ZnS Zinc Sulphide
Zinc Sulphide
(
ZnS
)Eigenschaften | |
Transmission Range % | 50 |
Transmission Range | 0.38 - 14 µm (thickness 2 mm ) |
Refractive Index | 2.351415@633 nm |
Reflection Loss | 14% @10 µm |
Residual Beam Wavelength | 30.5 mm |
Density | 4.09 g/cm3 |
Melting point | sublimation > 500°C |
Molecular Weight | 97.43 |
Thermal Conductivity | 27.2 W/(m·K) @298K |
Spec. Heat Capacity | 519.15 J/(kg·K) |
Thermal Expansion | 6.5 · 10-6 /K @208...473K |
Hardness (Mohs) | 160 (Indenter load 50g) |
Young's Modulus | 87.6 GPa |
Shear Modulus | 33 GPa |
Bulk Modulus | 80.41 GPa |
Rupture Modulus | 68.9 MPa |
Elastic Coefficient | C11 = 102; C12 = 64.6; C44 = 44.6 GPa |
Dielectric Constant | 8.393 @ (low frequency) |
Solubility in Water | unsoluble |
Crystal Structure | polycrystalline, synthetic, grain size < 200 µm |
Crystal Type | cubic Sphalerit type structure, a = 5,42 Å |
Lattice Constants | no cleavage |
Poisson Ratio | 0.3 |
Application | IR optics, FLIR (Forward Looking Infrared) Systems, 2 qualities (FLIR, ms) |
Remarks | more resistant than ZnSe, max. temperature for application: 300°C, reacts in combination with intense oxidizing agents and some acids, CVD grown plates. |
Remarkable |
|
ZnS – Zinc Sulphide: Korth Kristalle - Vom Rohkristall zur hochpräzisen Optik. Durchblick für alle Wellenlängen - Seit 72 Jahren züchten wir Kristalle und fertigen daraus hochpräzise optische Komponenten für alle Wellenlängen vom IR- bis zum VUV-Bereich. Unsere Produkte kommen in allen Bereichen zum Einsatz, in denen eine hochentwickelte, präzise technische Ausstattung unerlässlich ist – von der Analytik bis hin zur Medizin- und Raumfahrttechnik.
Contact/Inquiry
Korth Kristalle
Am Jägersberg 3
24161 Altenholz
+49 (0)431 - 36 90 50
+49 (0)431 - 36 90 525
Remarkable
- Polycrystalline material produced by CVD process (Chemical Vapor Deposition)
- Available in large plates (price correlates with the thickness of the plate)
- Two different qualities - ZnS (ms) and ZnS (FLIR) - which differ by their transmission properties
- Use for the wavelength range from 350 nm-14 µm for ZnS-ms and 400 nm-12 µm for ZnS-FLIR